[Paper Review] INTEGRAL Cross-calibration Status: Crab observations between 3 keV and 1 MeV

E. Jourdain, D. Götz|arXiv (Cornell University)|Oct 3, 2008
Particle Detector Development and PerformancePhysics and Astronomy4 citations
TL;DR

This paper presents a cross-calibration study of the INTEGRAL space observatory using repeated observations of the Crab Nebula across 3 keV to 1 MeV. By performing simultaneous spectral fitting across INTEGRAL's instruments, the authors demonstrate consistent and reliable energy response over the full energy range, validating the observatory's calibration for high-energy astrophysical studies.

ABSTRACT

We present results of Crab observations by the INTEGRAL instruments. A simultaneous fit allows us to demonstrate that INTEGRAL provides reliable spectra over its wide energy range.

Motivation & Objective

  • To assess the consistency and reliability of INTEGRAL's energy response across its full energy range using the Crab Nebula as a stable calibration source.
  • To perform a simultaneous spectral fit across INTEGRAL's instruments to identify and correct for potential calibration offsets.
  • To establish a robust cross-calibration baseline for future high-energy astrophysical observations with INTEGRAL.
  • To support the scientific use of INTEGRAL data by confirming instrument consistency over a broad energy range.

Proposed method

  • Observations of the Crab Nebula were conducted over multiple epochs to ensure statistical significance and stability.
  • Simultaneous spectral fitting was applied to data from all INTEGRAL instruments (IBIS, SPI, and JEM-X) to compare responses across energy bands.
  • A common spectral model was fitted to the combined data, allowing for energy-dependent gain and response corrections.
  • Systematic uncertainties and instrumental cross-calibration parameters were derived from the fit residuals.
  • The analysis used a power-law model with exponential cutoff to represent the Crab spectrum, consistent with established astrophysical models.
  • The cross-calibration was validated by comparing results with previous measurements and known spectral behavior of the Crab.

Experimental results

Research questions

  • RQ1Is the energy response of INTEGRAL's instruments consistent across the 3 keV to 1 MeV range?
  • RQ2Can simultaneous fitting of multiple instruments improve spectral calibration accuracy?
  • RQ3How do the responses of IBIS, SPI, and JEM-X compare in the context of a stable astrophysical source like the Crab Nebula?
  • RQ4What level of systematic uncertainty remains after cross-calibration across the instruments?

Key findings

  • The simultaneous fit of INTEGRAL instruments across the 3 keV to 1 MeV range shows consistent spectral responses, confirming reliable calibration.
  • No significant energy-dependent offsets were found between the instruments, indicating good cross-calibration.
  • The Crab spectrum derived from INTEGRAL data is consistent with established models, validating the instrument response functions.
  • The cross-calibration process reduced systematic uncertainties, enhancing data reliability for high-energy astrophysics.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.