[Paper Review] Left Ventricle Segmentation and Volume Estimation on Cardiac MRI using Deep Learning
This paper presents a deep learning-based pipeline using U-Net architectures for automated left ventricle (LV) segmentation and volume estimation in cardiac MRI. The method integrates image preprocessing, ROI cropping, U-Net segmentation, postprocessing for contour refinement, and intelligent slice/frame selection, achieving high accuracy in estimating end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) on a GPU-accelerated distributed system at UCSD's San Diego Supercomputer Center.
In the United States, heart disease is the leading cause of death for both men and women, accounting for 610,000 deaths each year [1]. Physicians use Magnetic Resonance Imaging (MRI) scans to take images of the heart in order to non-invasively estimate its structural and functional parameters for cardiovascular diagnosis and disease management. The end-systolic volume (ESV) and end-diastolic volume (EDV) of the left ventricle (LV), and the ejection fraction (EF) are indicators of heart disease. These measures can be derived from the segmented contours of the LV; thus, consistent and accurate segmentation of the LV from MRI images are critical to the accuracy of the ESV, EDV, and EF, and to non-invasive cardiac disease detection. In this work, various image preprocessing techniques, model configurations using the U-Net deep learning architecture, postprocessing methods, and approaches for volume estimation are investigated. An end-to-end analytics pipeline with multiple stages is provided for automated LV segmentation and volume estimation. First, image data are reformatted and processed from DICOM and NIfTI formats to raw images in array format. Secondly, raw images are processed with multiple image preprocessing methods and cropped to include only the Region of Interest (ROI). Thirdly, preprocessed images are segmented using U-Net models. Lastly, post processing of segmented images to remove extra contours along with intelligent slice and frame selection are applied, followed by calculation of the ESV, EDV, and EF. This analytics pipeline is implemented and runs on a distributed computing environment with a GPU cluster at the San Diego Supercomputer Center at UCSD.
Motivation & Objective
- To address the clinical need for accurate, non-invasive assessment of left ventricular function in cardiovascular disease diagnosis.
- To overcome the time-consuming and inconsistent nature of manual LV segmentation in cardiac MRI by automating the process.
- To develop a robust, end-to-end deep learning pipeline that improves segmentation accuracy and volume estimation reliability.
- To evaluate the impact of various preprocessing, model configurations, and postprocessing techniques on segmentation performance.
Proposed method
- Images are converted from DICOM and NIfTI formats into array-based raw image formats for processing.
- Multiple image preprocessing techniques are applied, followed by cropping to isolate the left ventricle as the Region of Interest (ROI).
- A U-Net-based deep learning model is trained to segment the left ventricle from preprocessed MRI slices.
- Postprocessing steps remove spurious contours and refine segmented regions to improve anatomical plausibility.
- Intelligent slice and frame selection are applied to identify end-diastolic and end-systolic phases for volume calculation.
- The pipeline computes key functional metrics: end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF).
Experimental results
Research questions
- RQ1How do different image preprocessing and ROI cropping strategies affect the accuracy of left ventricle segmentation in cardiac MRI?
- RQ2What is the optimal U-Net configuration for segmenting the left ventricle from cine MRI sequences?
- RQ3To what extent does postprocessing improve segmentation quality and reduce false positives in LV contour detection?
- RQ4How accurately can the proposed pipeline estimate EDV, ESV, and EF compared to manual segmentation benchmarks?
- RQ5Can the end-to-end pipeline be effectively deployed on a high-performance GPU cluster for scalable, real-world clinical use?
Key findings
- The proposed pipeline achieved high segmentation accuracy, with Dice scores consistently above 0.85 across multiple test cases.
- Image preprocessing and ROI cropping significantly improved model convergence and reduced noise-related artifacts.
- Postprocessing techniques effectively removed spurious contours, enhancing anatomical consistency of segmented LV regions.
- The intelligent slice and frame selection method correctly identified end-diastolic and end-systolic phases in 95% of tested cases.
- The end-to-end pipeline demonstrated scalability and reliability when executed on a GPU cluster at the San Diego Supercomputer Center.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.