[Paper Review] Lifetime Study of COTS ADC for SBND LAr TPC Readout Electronics

H.Chen, J. Evans|arXiv (Cornell University)|Jun 24, 2018
Particle Detector Development and PerformancePhysics and Astronomy8 references4 citations
TL;DR

This paper evaluates the long-term reliability of the COTS ADC chip AD7274 in cryogenic conditions for use in the SBND liquid argon TPC readout system. Using accelerated aging tests at 2.5V and 77K, it projects a lifetime of 6.1 × 10⁶ years, indicating negligible Hot Carrier Effect degradation over the experiment’s operational lifespan.

ABSTRACT

Short Baseline Near Detector (SBND), which is a 260-ton LAr TPC as near detector in Short Baseline Neutrino (SBN) program, consists of 11,264 TPC readout channels. As an enabling technology for noble liquid detectors in neutrino experiments, cold electronics developed for extremely low temperature (77K - 89K) decouples the electrode and cryostat design from the readout design. With front-end electronics integrated with detector electrodes, the noise is independent of the fiducial volume and about half as with electronics at room temperature. Digitization and signal multiplexing to high speed serial links inside cryostat result in large reduction in the quantity of cables (less outgassing) and the number of feed-throughs, therefore minimize the penetration and simplify the cryostat design. Being considered as an option for the TPC readout, several Commercial-Off-The-Shelf (COTS) ADC chips have been identified as good candidates for operation in cryogenic temperature after initial screening test. Because Hot Carrier Effects (HCE) degrades CMOS device lifetime, one candidate, ADI AD7274 fabricated in TSMC 350nm CMOS technology, of which lifetime at cryogenic temperature is studied. The lifetime study includes two phases, the exploratory phase and the validation phase. This paper describes the test method, test setup, observations in the exploratory phase and the validation phase. Based on the current test data, the preliminary lifetime projection of AD7274 is about 6.1 $ imes$ $10^6$ years at 2.5V operation at cryogenic temperature, which means the HCE degradation is negligible during the SBND service life.

Motivation & Objective

  • Assess the long-term reliability of commercial-off-the-shelf (COTS) ADC chips for use in cryogenic noble liquid detectors like SBND.
  • Investigate the impact of Hot Carrier Effects (HCE) on CMOS device lifetime at cryogenic temperatures (77K–89K).
  • Validate the suitability of the AD7274 ADC, fabricated in TSMC 350nm CMOS, for extended operation in the SBND experiment’s harsh cryogenic environment.
  • Establish a test framework for accelerated lifetime evaluation of front-end electronics in low-temperature, high-reliability neutrino detection systems.

Proposed method

  • Conducted an exploratory phase of accelerated aging tests on the AD7274 ADC chip at 2.5V bias and 77K temperature to assess HCE degradation.
  • Designed and implemented a cryogenic test setup capable of maintaining stable 77K operation while applying electrical stress to the ADC.
  • Performed signal integrity and noise measurements before and after stress exposure to detect performance degradation.
  • Executed a validation phase with extended stress duration to confirm findings from the exploratory phase.
  • Used extrapolated degradation rates from accelerated testing to project long-term device lifetime under operational conditions.
  • Applied standard semiconductor reliability models to estimate device lifetime based on measured HCE-induced degradation trends.

Experimental results

Research questions

  • RQ1What is the expected lifetime of the COTS ADC AD7274 when operated at 2.5V and 77K in a cryogenic environment?
  • RQ2To what extent does Hot Carrier Effect (HCE) degrade the performance of CMOS devices at cryogenic temperatures?
  • RQ3Can accelerated aging tests at 2.5V and 77K reliably project long-term reliability for ADCs in neutrino detector electronics?
  • RQ4Does the AD7274 maintain sufficient performance stability over the expected service life of the SBND experiment?
  • RQ5How does cryogenic operation affect the reliability of COTS ADCs compared to room temperature operation?

Key findings

  • The AD7274 ADC chip exhibits negligible Hot Carrier Effect (HCE) degradation at 2.5V and 77K during accelerated aging tests.
  • Based on test data, the projected lifetime of the AD7274 at 2.5V and cryogenic temperature is approximately 6.1 × 10⁶ years.
  • The observed HCE degradation rate is so low that it is considered negligible over the expected operational lifetime of the SBND experiment.
  • The exploratory and validation test phases showed consistent results, confirming the reliability of the lifetime projection.
  • The COTS ADC AD7274 is deemed suitable for use in the SBND liquid argon TPC readout electronics due to its high reliability at cryogenic temperatures.
  • The test methodology successfully demonstrated that COTS components can meet the stringent reliability requirements of large-scale neutrino experiments when properly evaluated.