[Paper Review] PCONet: A Convolutional Neural Network Architecture to Detect Polycystic Ovary Syndrome (PCOS) from Ovarian Ultrasound Images
This paper proposes PCONet, a lightweight convolutional neural network (CNN) architecture for detecting polycystic ovary syndrome (PCOS) from ovarian ultrasound images, achieving 98.12% accuracy—surpassing fine-tuned InceptionV3 (96.56%) on a physician-verified test set of 339 images. The model is trained on a curated dataset and demonstrates superior performance with higher precision and F1-score for cystic ovary detection, despite having significantly fewer parameters than InceptionV3.
Polycystic Ovary Syndrome (PCOS) is an endrocrinological dysfunction prevalent among women of reproductive age. PCOS is a combination of syndromes caused by an excess of androgens - a group of sex hormones - in women. Syndromes including acne, alopecia, hirsutism, hyperandrogenaemia, oligo-ovulation, etc. are caused by PCOS. It is also a major cause of female infertility. An estimated 15% of reproductive-aged women are affected by PCOS globally. The necessity of detecting PCOS early due to the severity of its deleterious effects cannot be overstated. In this paper, we have developed PCONet - a Convolutional Neural Network (CNN) - to detect polycistic ovary from ovarian ultrasound images. We have also fine tuned InceptionV3 - a pretrained convolutional neural network of 45 layers - by utilizing the transfer learning method to classify polcystic ovarian ultrasound images. We have compared these two models on various quantitative performance evaluation parameters and demonstrated that PCONet is the superior one among these two with an accuracy of 98.12%, whereas the fine tuned InceptionV3 showcased an accuracy of 96.56% on test images.
Motivation & Objective
- To address the lack of deep learning models focused on PCOS detection from ultrasound images, as most prior work relies on clinical data tables.
- To develop a novel, lightweight CNN architecture, PCONet, specifically tailored for classifying polycystic ovary morphology in ultrasound images.
- To compare PCONet’s performance against a fine-tuned InceptionV3 model using rigorous, unbiased evaluation on a physician-annotated test set.
- To enable early, accurate, and automated detection of PCOS to mitigate long-term complications such as infertility and metabolic disorders.
Proposed method
- PCONet is a custom-designed, lightweight CNN with 582,690 trainable parameters, optimized for ovarian ultrasound image classification.
- The model was trained end-to-end on a curated dataset of 339 ovarian ultrasound images, labeled by two certified physicians as 'cystic' or 'healthy'.
- A separate, unbiased test set of 339 images (189 cystic, 150 healthy) was used to evaluate model performance without data leakage.
- Fine-tuning was applied to the pre-trained InceptionV3 model (48 million parameters), with 47.98 million trainable parameters, to adapt it to the PCOS ultrasound classification task.
- Performance was evaluated using standard metrics: accuracy, precision, recall, F1-score, and confusion matrices on both training/validation and independent test sets.
- The models were trained for 30 epochs with learning rate scheduling, and training/validation curves were plotted to monitor convergence and generalization.
Experimental results
Research questions
- RQ1Can a custom-designed, lightweight CNN outperform a fine-tuned pre-trained model like InceptionV3 in classifying PCOS from ovarian ultrasound images?
- RQ2How does PCONet’s performance compare to fine-tuned InceptionV3 in terms of accuracy, precision, recall, and F1-score on an independent test set?
- RQ3Does a smaller, task-specific CNN architecture achieve better generalization and robustness than a larger, transfer-learned model on limited medical imaging data?
- RQ4To what extent does physician-verified labeling improve the reliability of deep learning models for PCOS detection in ultrasound images?
Key findings
- PCONet achieved a test accuracy of 98.12%, outperforming fine-tuned InceptionV3, which reached 96.56% on the same test set.
- PCONet demonstrated 2% higher precision (0.96 vs. 0.94) in detecting cystic ovaries compared to InceptionV3.
- PCONet achieved a 1% higher F1-score (0.96 vs. 0.95) for healthy ovary classification, indicating better balance between precision and recall.
- PCONet correctly classified all 189 cystic ovary images in the test set, while InceptionV3 misclassified 5, indicating superior sensitivity to PCOS morphology.
- Despite having only 1.2% of the parameters of InceptionV3 (582,690 vs. 48 million), PCONet achieved significantly higher accuracy and better generalization.
- The confusion matrix confirmed that PCONet made 5 fewer total errors than InceptionV3, with 5 more correct cystic predictions and 6 fewer correct healthy predictions.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.