[Paper Review] Predicting Semen Motility using three-dimensional Convolutional Neural Networks
This paper proposes a 3D convolutional neural network (3D ResNet) to predict sperm motility from microscopic videos, achieving 87.5% accuracy on a 9-sample test set using only 50 frames per video. By leveraging spatial-temporal features from video clips and optimizing for low-data regimes, the method enables fast, accurate, and reproducible semen analysis with an average inference time of 400ms, offering a scalable alternative to manual or traditional CASA methods.
Manual and computer aided methods to perform semen analysis are time-consuming, requires extensive training and prone to human error. The use of classical machine learning and deep learning based methods using videos to perform semen analysis have yielded good results. The state-of-the-art method uses regular convolutional neural networks to perform quality assessments on a video of the provided sample. In this paper we propose an improved deep learning based approach using three-dimensional convolutional neural networks to predict sperm motility from microscopic videos of the semen sample. We make use of the VISEM dataset that consists of video and tabular data of semen samples collected from 85 participants. We were able to achieve good results from significantly less data points. Our models indicate that deep learning based automatic semen analysis may become a valuable and effective tool in fertility and IVF labs.
Motivation & Objective
- To develop a deep learning-based method for automated semen analysis that reduces reliance on manual or expensive CASA systems.
- To address the limitations of existing methods, including high time cost, data sensitivity, and human error in manual evaluation.
- To improve accuracy and speed in predicting sperm motility using video data, particularly in low-resource fertility clinics.
- To evaluate whether integrating tabular clinical data enhances model performance in sperm motility classification.
Proposed method
- The study employs 3D convolutional neural networks (3D ResNet18 and 3D ResNet34) to extract spatial-temporal features from 50-frame video clips of semen samples.
- Each video is converted to grayscale to reduce data size and improve efficiency, preserving motion and structural patterns relevant to motility.
- The models are trained using weighted cross-entropy loss with class balancing to mitigate data imbalance (52 progressively motile, 9 non-progressively motile, 24 immotile samples).
- A one-cycle learning rate scheduler with weight decay and gradient clipping (0.1) is used to stabilize training and prevent exploding gradients.
- Tabular data (e.g., BMI, serum hormone levels) is concatenated with video features in some models to explore multimodal input, though this is found to reduce performance.
- All models are implemented in PyTorch, with inference times measured at ~400ms per sample, indicating real-time applicability.
Experimental results
Research questions
- RQ1Can 3D convolutional neural networks effectively classify sperm motility from limited video data, outperforming traditional or 2D CNN-based approaches?
- RQ2How does the inclusion of tabular clinical data affect the performance of video-based sperm motility classification models?
- RQ3To what extent does model depth (ResNet18 vs. ResNet34) influence accuracy and generalization in this low-data regime?
- RQ4Does the proposed method achieve sufficient accuracy and speed to be viable for real-world clinical deployment in fertility and IVF labs?
Key findings
- The 3D ResNet18 model achieved 100% accuracy on both validation and test sets, indicating strong generalization on the small dataset.
- The 3D ResNet18 + tabular data model reached 88.89% accuracy on the test set, demonstrating that multimodal input can improve performance despite data imbalance.
- The 3D ResNet34 + tabular data model achieved 87.5% accuracy on validation and 77.78% on test, indicating that deeper architectures with redundant features may overfit or degrade performance.
- The best-performing model achieved 87.5% test accuracy with an average inference time of 400 milliseconds, supporting real-time deployment potential.
- The study found that tabular data introduced redundancy and potential data leakage, reducing model performance, suggesting that video-only inputs are more effective for motility prediction.
- The results establish a new baseline for classification-based sperm motility prediction on the VISEM dataset, enabling future work in automated semen analysis.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.