[Paper Review] Reply to Schneider et al. [arXiv:1407.4127v1]
This paper refutes claims by Schneider et al. that negative absolute temperatures and a symmetric entropy function S(E) = S(−E) are thermodynamically consistent for systems with bounded energy spectra. It argues that the Gibbs entropy S_G = ln Ω, derived from the cumulative density of states, is the only entropy definition that satisfies the zeroth, first, and second laws of thermodynamics in isolated systems, especially when ensemble equivalence fails. The key result is that negative temperatures are not physically valid in microcanonical thermodynamics, and the canonical ensemble is inapplicable to isolated systems like those in the 2013 Braun experiment.
We respond to invalid criticism in the recent Comment by Schneider et al. [arXiv:1407.4127v1]
Motivation & Objective
- To correct fundamental errors in Schneider et al.'s claim that negative absolute temperatures are thermodynamically consistent in isolated systems with bounded energy spectra.
- To demonstrate that the canonical ensemble is inapplicable to the 2013 Braun experiment, which involved a thermally isolated ultracold atomic gas.
- To establish that the Gibbs entropy S_G = ln Ω, based on the cumulative density of states, is the only entropy definition that satisfies all three laws of thermodynamics for isolated systems.
- To refute the postulate S(E) = S(−E) by showing it violates physical asymmetry between ground and highest energy states, contradicting thermodynamic principles and experimental reality.
- To clarify historical and conceptual errors in terminology and interpretation, particularly regarding the attribution of the entropy formula to Hertz instead of Gibbs.
Proposed method
- Uses exact results from Gibbs (1875), Hertz (1910), and Khinchin (1949) to show that the Gibbs entropy S_G = ln Ω is the unique entropy satisfying the zeroth, first, and second laws.
- Analyzes the microcanonical density operator ρ = δ(E − H)/ω(E), where ω(E) is the density of states, and derives Ω(E) = ∫₀ᴱ ω(E′) dE′ to define S_G.
- Demonstrates that ensemble equivalence fails for systems with non-monotonic density of states, making the canonical ensemble invalid for isolated systems with bounded spectra.
- Constructs a model Hamiltonian with non-monotonic ω(E) = 1/4 + 1/4 sin(2E/ε) + E/ε to show that the same temperature T_G can correspond to vastly different energies, invalidating temperature-based heat flow predictions.
- Argues that the canonical ensemble is only valid when a system is coupled to an infinite heat bath; this does not apply to the isolated system in the 2013 Braun experiment.
- Reveals that the symmetry S(E) = S(−E) is physically meaningless because it equates the ground state and the highest energy state, which are not thermodynamically equivalent—e.g., energy can be added to the ground state but not to the highest-energy state.
Experimental results
Research questions
- RQ1Can negative absolute temperatures be consistently described within microcanonical thermodynamics for isolated systems with bounded energy spectra?
- RQ2Is the entropy function S(E) = S(−E) physically valid, given that it equates the ground state and the highest-energy state?
- RQ3Does the canonical ensemble provide a valid description for the 2013 Braun experiment involving an isolated ultracold atomic gas with population inversion?
- RQ4Which entropy definition—Gibbs S_G = ln Ω or Boltzmann S_B = ln(εω)—satisfies the zeroth, first, and second laws of thermodynamics for isolated systems?
- RQ5Is the microcanonical temperature T_G a reliable predictor of heat flow between two isolated systems, or does it fail due to non-monotonic density of states?
Key findings
- The claim that negative absolute temperatures are thermodynamically consistent is incorrect, as it violates the second law and implies Carnot efficiencies greater than one, which would allow perpetual motion.
- The entropy S_G = ln Ω, derived from the cumulative density of states, is the only entropy definition that satisfies the zeroth, first, and second laws of thermodynamics for isolated systems.
- The canonical ensemble is inapplicable to the 2013 Braun experiment because the system was isolated and all atoms were subject to potential changes, requiring a microcanonical description.
- Ensemble equivalence does not hold for systems with non-monotonic density of states, meaning the same temperature T_G can correspond to multiple energy values, invalidating temperature-based heat flow predictions.
- The symmetry S(E) = S(−E) is physically meaningless because it equates the ground state and the highest-energy state, which are not thermodynamically equivalent—energy can be added to the ground state but not to the highest-energy state.
- The term 'Hertz entropy' is historically inaccurate; Hertz explicitly acknowledged Gibbs’s earlier work, making Gibbs the rightful originator of the entropy formula S = ln Ω.
Read this paper