Skip to main content
QUICK REVIEW

[Paper Review] Robust Optimal Power Flow with Wind Integration Using Conditional Value-at-Risk

Yu Zhang, Georgios B. Giannakis|arXiv (Cornell University)|Oct 28, 2013
Electric Power System OptimizationEngineering12 references6 citations
TL;DR

This paper proposes a robust DC optimal power flow (OPF) framework for power systems with high wind penetration, using conditional value-at-risk (CVaR) as a risk-aware regularizer to minimize both conventional generation costs and energy transaction costs under wind power uncertainty. The method employs sample average approximation (SAA) to bypass computationally intractable high-dimensional integrals, resulting in a convex optimization problem that reduces expected cost and variance compared to risk-insensitive dispatch, as validated on the IEEE 30-bus system with real wind data.

ABSTRACT

Integrating renewable energy into the power grid requires intelligent risk-aware dispatch accounting for the stochastic availability of renewables. Toward achieving this goal, a robust DC optimal flow problem is developed in the present paper for power systems with a high penetration of wind energy. The optimal dispatch is obtained as the solution to a convex program with a suitable regularizer, which is able to mitigate the potentially high risk of inadequate wind power. The regularizer is constructed based on the energy transaction cost using conditional value-at-risk (CVaR). Bypassing the prohibitive high-dimensional integral, the distribution-free sample average approximation method is efficiently utilized for solving the resulting optimization problem. Case studies are reported to corroborate the efficacy of the novel model and approach tested on the IEEE 30-bus benchmark system with real operation data from seven wind farms.

Motivation & Objective

  • To address the challenge of stochastic wind power availability in optimal power flow (OPF) by incorporating risk-aware dispatch strategies.
  • To reduce the risk of inadequate wind power supply while minimizing total system costs, including generation and energy transaction costs.
  • To develop a convex optimization framework that is computationally tractable despite the high-dimensional uncertainty in wind power forecasts.
  • To enable smart utilization of wind energy by leveraging location-specific wind prices and risk thresholds through CVaR-based regularization.
  • To validate the proposed model using real-world wind farm data on the IEEE 30-bus system under varying load and wind conditions.

Proposed method

  • Formulates a robust DC-OPF problem with a CVaR-based regularizer that penalizes high transaction costs in the tail of the loss distribution, thereby limiting the risk of wind power shortage.
  • Uses the conditional value-at-risk (CVaR) metric at a confidence level β = 0.95 to quantify the expected cost of energy transactions beyond the VaR threshold, ensuring risk-averse dispatch.
  • Applies the sample average approximation (SAA) method to replace the intractable high-dimensional expectation in the CVaR regularizer with a finite-sample average, enabling efficient computation without distributional assumptions.
  • Solves the resulting convex optimization problem using SAA, which transforms the stochastic program into a tractable, distribution-free, and scalable form.
  • Incorporates physical constraints such as power balance, generator limits, and wind power truncation to zero for negative values, ensuring feasibility.
  • Employs empirical covariance estimation from real wind data (589 hours, 2012) to model correlated wind forecasts across multiple buses.

Experimental results

Research questions

  • RQ1How can risk-aware optimal power flow be formulated to mitigate the high cost of wind power shortage in systems with high wind penetration?
  • RQ2Can a CVaR-based regularizer effectively balance generation cost and transaction cost in a convex optimization framework for DC-OPF?
  • RQ3How does the proposed SAA-based approach compare to risk-insensitive dispatch in terms of expected cost and variance under real wind data?
  • RQ4To what extent does the overload ratio of demand affect the transaction cost and LMPs under CVaR-aware risk control?
  • RQ5How does the location-specific wind price influence the optimal dispatch of wind power in the risk-aware framework?

Key findings

  • The CVaR-based risk-limiting dispatch reduces the mean total cost from 419.87 (no risk control) to 396.40, a 5.6% improvement, while significantly lowering variance from 856.24 to 126.09.
  • The optimal cost decreases with increasing regularization weight μ, as higher μ imposes a stronger penalty on transaction costs, leading to reduced wind power commitment and increased conventional generation.
  • The CDF of total costs shows that the CVaR-based scheme consistently incurs lower costs than the risk-insensitive approach, confirming its robustness and risk mitigation capability.
  • The optimal dispatch schedules higher wind power at bus 7, where the purchase price is lowest, enabling lower conventional generation and total cost, demonstrating smart wind utilization.
  • Under increasing demand overload (γ = 0 to 0.3), the total cost increases as expected, but the transaction cost remains nearly constant due to the CVaR-based risk control mechanism.
  • Locational marginal prices (LMPs) increase with overload ratio and exhibit congestion effects, confirming that transmission constraints emerge under high demand, which the CVaR model effectively manages.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.