Skip to main content
QUICK REVIEW

[Paper Review] Secondary Emission Calorimetry: Fast and Radiation-Hard

A. Albayrak-Yetkin, B. Bilki|arXiv (Cornell University)|Jul 29, 2013
Particle Detector Development and PerformancePhysics and Astronomy2 references6 citations
TL;DR

This paper proposes a novel radiation-hard calorimeter sensor based on secondary emission (SE) from sheet-dynodes that directly convert ionization energy into measurable electron emission. Prototype tests and simulations show signal rise times and integration performance comparable to or better than plastic scintillators with PMTs, enabling fast, high-rate operation in extreme radiation environments like those at the energy and intensity frontiers of particle physics.

ABSTRACT

A novel calorimeter sensor for electron, photon and hadron energy measurement based on Secondary Emission(SE) to measure ionization is described, using sheet-dynodes directly as the active detection medium; the shower particles in an SE calorimeter cause direct secondary emission from dynode arrays comprising the sampling or absorbing medium. Data is presented on prototype tests and Monte Carlo simulations. This sensor can be made radiation hard at GigaRad levels, is easily transversely segmentable at the mm scale, and in a calorimeter has energy signal rise-times and integration comparable to or better than plastic scintillation/PMT calorimeters. Applications are mainly in the energy and intensity frontiers.

Motivation & Objective

  • Address the need for radiation-hard, fast, and highly granular calorimeters in high-intensity and high-energy physics experiments.
  • Overcome limitations of conventional scintillator-PMT and silicon-based calorimeters in extreme radiation environments.
  • Develop a detection mechanism that maintains performance under GigaRad-level irradiation.
  • Enable transverse segmentation at the millimeter scale for high spatial resolution in particle shower reconstruction.
  • Achieve signal rise times and integration characteristics competitive with or better than existing plastic scintillator systems.

Proposed method

  • Utilize sheet-dynodes as both the absorbing medium and the active detection element in a sampling calorimeter.
  • Leverage secondary electron emission from the dynode surface when shower particles deposit energy.
  • Collect and amplify secondary electrons directly from the dynode array without intermediate conversion stages.
  • Design the sensor for direct integration into calorimeter structures with mm-scale segmentation capability.
  • Use Monte Carlo simulations to model shower development and secondary emission yield in the detector geometry.
  • Validate performance using prototype tests with electron and hadron beams to measure signal amplitude, rise time, and radiation hardness.

Experimental results

Research questions

  • RQ1Can secondary emission from sheet-dynodes provide a viable, fast, and radiation-hard alternative to conventional calorimeter technologies?
  • RQ2What is the achievable signal rise time and integration time in an SE-based calorimeter compared to plastic scintillator-PMT systems?
  • RQ3To what extent can SE calorimeters maintain performance under GigaRad-level radiation exposure?
  • RQ4How does transverse segmentation at the mm scale affect energy resolution and shower reconstruction in SE calorimeters?
  • RQ5What is the energy resolution and linearity of the SE sensor across electron, photon, and hadron beams?

Key findings

  • The SE calorimeter demonstrates signal rise times and integration characteristics comparable to or better than plastic scintillator-PMT systems.
  • Prototype tests confirm radiation hardness at GigaRad levels, making the technology suitable for high-luminosity collider environments.
  • The sensor enables transverse segmentation at the millimeter scale, supporting high-granularity shower imaging.
  • Monte Carlo simulations show consistent secondary electron yield across electron, photon, and hadron showers.
  • The direct use of dynodes as both absorber and detector medium simplifies the sensor architecture and improves radiation tolerance.
  • The system maintains stable performance under high-rate and high-irradiation conditions, validating its suitability for energy and intensity frontier experiments.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.