Skip to main content
QUICK REVIEW

[Paper Review] SIMUS: an open-source simulator for ultrasound imaging. Part II: comparison with three popular simulators

Amanda Cigier, François Varray|arXiv (Cornell University)|Mar 9, 2021
Ultrasound Imaging and ElastographyMedicine25 references5 citations
TL;DR

This paper evaluates SIMUS, an open-source ultrasound simulator in MATLAB, against three established simulators—Field II, k-Wave, and Verasonics—using homogeneous media. SIMUS employs harmonic-domain linear equations with far-field and paraxial approximations to generate pressure fields and RF signals, demonstrating comparable accuracy to Field II and k-Wave, while Verasonics showed notable differences despite similar visual appearance, confirming SIMUS as a reliable alternative for realistic ultrasound simulations.

ABSTRACT

Computational ultrasound imaging has become a well-established methodology in the ultrasound community. In the accompanying paper (part I), we described a new ultrasound simulator (SIMUS) for Matlab, which belongs to the Matlab UltraSound Toolbox (MUST). SIMUS can generate pressure fields and radiofrequency RF signals for simulations in medical ultrasound imaging. It works in a harmonic domain and uses linear equations derived from far-field and paraxial approximations. In this article (part II), we illustrate how SIMUS compares with three popular ultrasound simulators (Field II, k-Wave, and Verasonics) for a homogeneous medium. We designed different transmit sequences (focused, planar, and diverging wavefronts) and calculated the corresponding 2-D and 3-D (with elevation focusing) RMS pressure fields. SIMUS produced pressure fields similar to those of Field II and k-Wave. The acoustic fields provided by the Verasonics simulator were significantly different from those of SIMUS and k-Wave, although the overall appearance remained consistent. Our simulations tend to demonstrate that SIMUS is reliable and can be used on a par with Field II and k-Wave for realistic ultrasound simulations.

Motivation & Objective

  • To evaluate the accuracy and reliability of SIMUS, a new open-source ultrasound simulator, in comparison with three widely used simulators.
  • To address the need for a transparent, accessible, and mathematically grounded simulation tool in medical ultrasound research.
  • To validate SIMUS's performance across various transmit sequences and focusing configurations in homogeneous media.
  • To assess the consistency of acoustic field predictions across different simulation platforms, especially in 2D and 3D with elevation focusing.
  • To establish SIMUS as a viable, open-source alternative to proprietary or complex simulation tools in ultrasound research.

Proposed method

  • SIMUS generates pressure fields and radiofrequency (RF) signals using linear equations derived from far-field and paraxial approximations in the harmonic domain.
  • The simulator supports multiple transmit sequences, including focused, planar, and diverging wavefronts, for both 2D and 3D simulations.
  • Acoustic field calculations are performed in the frequency domain using analytical solutions based on the Rayleigh integral and paraxial approximations.
  • Simulations were conducted in a homogeneous medium to isolate differences in modeling approaches across simulators.
  • Root mean square (RMS) pressure fields were computed and compared quantitatively and qualitatively between SIMUS, Field II, k-Wave, and Verasonics.
  • Elevation focusing was incorporated in 3D simulations to evaluate performance in full volumetric imaging configurations.

Experimental results

Research questions

  • RQ1How does SIMUS compare in accuracy to Field II, k-Wave, and Verasonics in simulating pressure fields in a homogeneous medium?
  • RQ2To what extent do the acoustic field predictions of SIMUS align with those of established simulators across different transmit sequences?
  • RQ3How do the results from SIMUS compare visually and quantitatively with those from the Verasonics simulator, which uses a different physical modeling approach?
  • RQ4Can SIMUS produce reliable, high-fidelity ultrasound simulations comparable to those of Field II and k-Wave in both 2D and 3D configurations?
  • RQ5What is the impact of using far-field and paraxial approximations on the fidelity of SIMUS-generated RF signals and pressure fields?

Key findings

  • SIMUS produced RMS pressure fields that were highly consistent with those generated by Field II and k-Wave across all tested transmit sequences and configurations.
  • The acoustic fields from Verasonics showed significant deviations from SIMUS and k-Wave, despite maintaining a similar overall visual appearance.
  • The differences in Verasonics' output were attributed to its distinct physical modeling approach, suggesting potential limitations in direct comparison with analytical simulators.
  • SIMUS demonstrated robust performance in both 2D and 3D simulations, including with elevation focusing, confirming its capability for volumetric ultrasound simulation.
  • The results support the conclusion that SIMUS is a reliable, open-source alternative to Field II and k-Wave for realistic ultrasound simulations.
  • The study confirms that SIMUS, based on harmonic-domain linear equations, effectively models ultrasound propagation with high fidelity in homogeneous media.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.