[Paper Review] SiPM Gain Stabilization Studies for Adaptive Power Supply

G. Eigen, Are Sivertsen Træet|arXiv (Cornell University)|Feb 29, 2016
Particle Detector Development and PerformancePhysics and Astronomy4 citations
TL;DR

This study demonstrates SiPM gain stabilization within ±0.5% across 20–30°C using temperature-dependent bias voltage adjustment, validated on four new SiPMs (three Hamamatsu with trenches, one KETEK) via automated, high-precision measurements in a CERN climate chamber. The method relies on calibrated dG/dV and dG/dT measurements to derive optimal V(T) correction, enabling stable performance in large-scale detector systems like analog hadron calorimeters.

ABSTRACT

We present herein gain stabilization studies of SiPMs using a climate chamber at CERN. We present results for four detectors not tested before, three from Hamamatsu and one from KETEK. Two of the Hamamatsu SiPMs are novel sensors with trenches that reduce cross talk. We use an improved readout system with a digital oscilloscope controlled with a dedicated LabView program. We improved and automized the analysis to deal with large datasets. We have measured the gain-versus-bias-voltage dependence at fixed temperature and gain-versus-temperature dependence at fixed bias voltage to determine the bias voltage dependence on temperature $V(T)$ for stable gain. We show that the gain remains stable to better than $\pm 0.5\%$ in the $20^\circ m C - 30^\circ C$ temperature range if the bias voltage is properly adjusted with temperature.

Motivation & Objective

  • To achieve SiPM gain stability within ±0.5% across the 20–30°C temperature range for use in large-scale detector systems.
  • To measure the temperature dependence of SiPM gain (dG/dT) and bias voltage dependence (dG/dV) for accurate V(T) correction.
  • To validate the method on four new SiPMs not previously tested, including novel Hamamatsu sensors with trench structures to reduce crosstalk.
  • To implement temperature-compensated bias voltage control into the power distribution system of an analog hadron calorimeter.
  • To improve data acquisition and analysis through automated LabView-controlled oscilloscopes and waveform processing for large datasets.

Proposed method

  • Conducted gain-versus-bias-voltage (dG/dV) and gain-versus-temperature (dG/dT) measurements using a climate chamber at CERN across 1–50°C.
  • Employed a digital LeCroy 6104 oscilloscope (12-bit ADC, 2.5 GS/s) with a custom LabView program for automated data acquisition and bias voltage control.
  • Used a voltage-operational two-stage preamplifier (8/25 ns) and a current-operational one-stage preamplifier (2/7 ns), with only the former proving stable across all temperatures.
  • Illuminated SiPMs with blue light via optical fiber and mirror, triggered by an external light pulser at 10 kHz to minimize noise.
  • Processed waveforms by subtracting DC offset and integrating 50,000 waveforms over a 74 ns window to generate photoelectron spectra.
  • Fitted photoelectron spectra using a likelihood function combining signal and background components to extract gain and afterpulsing fractions.

Experimental results

Research questions

  • RQ1Can SiPM gain be stabilized to within ±0.5% across the 20–30°C temperature range using temperature-dependent bias voltage adjustment?
  • RQ2How does the dG/dT and dG/dV dependence vary across different SiPM types, including novel trench-structured sensors?
  • RQ3To what extent does afterpulsing affect gain stability, and is it temperature-dependent?
  • RQ4Can a single bias voltage adjustment stabilize multiple similar SiPMs simultaneously in a large-scale detector system?
  • RQ5What is the impact of measurement system instability (e.g., preamplifier drift) on gain calibration accuracy?

Key findings

  • For SiPM B2 (Hamamatsu, 15 µm pitch), gain stabilization was achieved with a deviation of less than 1% across the 5–45°C range.
  • For LCT4#6 and LCT4#9 (Hamamatsu, 50 µm pitch with trenches), overcorrection due to using Hamamatsu’s specified dV/dT (60 mV/°C) instead of measured 53.9 mV/°C led to a ±1.2% deviation in the 20–30°C range.
  • For KETEK W12 (3×3 mm², 20 µm pitch), overcorrection using 21.3 mV/°C instead of the measured 17.2 mV/°C resulted in a ±4.1 mV/°C error, degrading stability.
  • Afterpulsing fraction R increased quadratically with overvoltage but showed no significant temperature dependence, indicating it does not compromise gain stabilization.
  • The current-operational preamplifier became unstable at higher temperatures, limiting usable data to only the voltage-operational preamplifier.
  • A follow-up study with four SiPMs tested simultaneously using four identical voltage-operational preamplifiers confirmed stable performance for 30 SiPMs, except for two CPTA sensors, with results pending final publication.