TL;DR

US-JEPA introduces a static-teacher SALT-based JEPA method for ultrasound, learning latent representations in a masked embedding space and achieving strong linear-probing performance on UltraBench across eight tasks.

ABSTRACT

Ultrasound (US) imaging poses unique challenges for representation learning due to its inherently noisy acquisition process. The low signal-to-noise ratio and stochastic speckle patterns hinder standard self-supervised learning methods relying on a pixel-level reconstruction objective. Joint-Embedding Predictive Architectures (JEPAs) address this drawback by predicting masked latent representations rather than raw pixels. However, standard approaches depend on hyperparameter-brittle and computationally expensive online teachers updated via exponential moving average. We propose US-JEPA, a self-supervised framework that adopts the Static-teacher Asymmetric Latent Training (SALT) objective. By using a frozen, domain-specific teacher to provide stable latent targets, US-JEPA decouples student-teacher optimization and pushes the student to expand upon the semantic priors of the teacher. In addition, we provide the first rigorous comparison of all publicly available state-of-the-art ultrasound foundation models on UltraBench, a public dataset benchmark spanning multiple organs and pathological conditions. Under linear probing for diverse classification tasks, US-JEPA achieves performance competitive with or superior to domain-specific and universal vision foundation model baselines. Our results demonstrate that masked latent prediction provides a stable and efficient path toward robust ultrasound representations.

Motivation & Objective

  • Address robustness and data efficiency in ultrasound representation learning due to noise and speckle artifacts.
  • Develop a JEPA-based self-supervised framework that operates in latent space using a fixed domain-specific teacher.
  • Mitigate reliance on pixel-level reconstruction by focusing on latent, semantic prediction.
  • Standardize evaluation by benchmarking all public ultrasound foundation models on UltraBench with linear probing.

Proposed method

  • Adopt SALT: freeze a domain-specific teacher (URFM) to provide stable latent targets.
  • Use a masked latent prediction objective that predicts target embeddings from a context block in the same image.
  • Incorporate Ultrasound Region-Conditioning (USrc) to restrict masking to ultrasound-valid regions and avoid non-anatomical content.
  • Train a context encoder (ViT-B/16) and a predictor to minimize Smooth L1 distance to frozen teacher embeddings.
  • Pretrain on a large public ultrasound corpus (~4.73M frames from 49 datasets).
  • Evaluate with standardized UltraBench linear probes across eight classification tasks.
Figure 1 : USrc-JEPA framework. Here we show the model training framework with USrc. URFM is the frozen teacher that extracts target embeddings. The student and predictor are jointly optimized with $\mathcal{L}_{US-JEPA}$ to align with the target.
Figure 1 : USrc-JEPA framework. Here we show the model training framework with USrc. URFM is the frozen teacher that extracts target embeddings. The student and predictor are jointly optimized with $\mathcal{L}_{US-JEPA}$ to align with the target.

Experimental results

Research questions

  • RQ1Can a static-teacher SALT framework improve latent-space ultrasound representations compared to EMA-based JEPA and domain-specific baselines?
  • RQ2How does US-JEPA perform in few-shot linear probing across diverse ultrasound tasks?
  • RQ3Is the learned latent space robust to domain-specific artifacts and corruption common in ultrasound imaging?
  • RQ4Does restricting targets/contexts to ultrasound-valid regions (USrc) improve representation quality?
  • RQ5How do public ultrasound foundation models compare under a standardized UltraBench benchmark with linear probing?

Key findings

  • US-JEPA and USrc-JEPA achieve state-of-the-art linear-probing performance on five of eight UltraBench tasks.
  • On MMOTU (eight-class ovarian tumor) US-JEPA achieves 52.2% macro F1, surpassing URFM by 9.5%.
  • US-JEPA and USrc-JEPA show strong robustness to domain-specific corruptions, especially speckle noise, outperforming baselines at high corruption levels.
  • In few-shot settings, US-JEPA features provide up to 18% higher macro F1 than URFM and USFM when labeled data <10%.
  • US-JEPA attains competitive results versus domain-specific and universal baselines, and often surpasses them, while enabling standardized, public benchmarking.
Figure 2 : Distribution of pretraining data. To characterize the dataset composition at the organ level, we report the distribution of a. temporal sequences, including videos and volumes ( $n_{v}$ ), and b. individual static frames ( $n_{f}$ ).
Figure 2 : Distribution of pretraining data. To characterize the dataset composition at the organ level, we report the distribution of a. temporal sequences, including videos and volumes ( $n_{v}$ ), and b. individual static frames ( $n_{f}$ ).

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.