This paper demonstrates that smartphone CMOS cameras can detect and classify gamma radiation by analyzing patterns of lit pixels caused by ionizing electrons from gamma rays. Using a low-complexity algorithm, it achieves limited energy resolution by correlating the fraction of line-like pixel groups with gamma energy, enabling basic spectroscopy and dose rate measurement with off-the-shelf phones.
The CMOS camera found in many cellphones is sensitive to ionized electrons. Gamma rays penetrate into the phone and produce ionized electrons that are then detected by the camera. Thermal noise and other noise needs to be removed on the phone, which requires an algorithm that has relatively low memory and computational requirements. The continuous high-delta algorithm described fits those requirements. Only a small fraction of the energy of even the electron is deposited in the camera sensor, so direct methods of measuring the energy cannot be used. The fraction of groups of lit up pixels that are lines is correlated with the energy of the gamma rays. This correlation under certain conditions allows limited low resolution energy resolution to be performed.
Motivation & Objective
- To evaluate the feasibility of using consumer smartphone CMOS cameras as low-cost gamma radiation detectors.
- To develop a lightweight algorithm for noise suppression and radiation event detection suitable for mobile devices.
- To explore the potential for limited energy resolution by analyzing spatial patterns of pixel activation.
- To assess the practicality of using smartphones for radiation monitoring in real-world scenarios, including dose rate measurement and source direction estimation.
Proposed method
- Captured images from smartphone cameras with lenses covered to block visible light, enabling detection of ionization events from gamma rays.
- Applied the continuous high-delta algorithm to identify and filter noise, focusing on groups of lit pixels with line-like structures.
- Correlated the fraction of line-like pixel groups with gamma ray energy, leveraging Compton scattering and photoelectric effect physics.
- Used silicon surface barrier detectors as proxies to model the response of CMOS sensors to electron deposition in silicon.
- Processed data on a server side to perform low-resolution spectroscopy and dose rate estimation from pixel group counts.
- Evaluated directional detection potential by comparing front and back camera responses under varying source angles.
Experimental results
Research questions
- RQ1Can smartphone CMOS sensors detect gamma radiation through ionization events in the sensor substrate?
- RQ2To what extent can the continuous high-delta algorithm effectively isolate radiation-induced pixel groups from thermal and electronic noise?
- RQ3Is there a measurable correlation between the fraction of line-like pixel groups and the energy of incident gamma rays?
- RQ4Can the front and back cameras of a smartphone be used to estimate the direction of a gamma source?
- RQ5How does the performance of different smartphone models compare in terms of sensitivity and consistency for radiation detection?
Key findings
- The Nexus S smartphone exhibited the highest sensitivity, detecting 0.203 groups per mrem/hr per image under 1 R/hr 60Co exposure.
- The Galaxy SIII showed excessive camera noise that degraded performance, even after software filtering.
- Intra-model variance between two Nexus S phones was low (average 3% change across orientations), indicating consistent performance within the same model.
- The fraction of line-like pixel groups showed a measurable correlation with gamma energy, enabling limited low-resolution spectroscopy.
- The ratio of groups detected by front and back cameras showed potential for source direction estimation, though practical implementation requires high-precision time and position synchronization.
- The method achieved detectable dose rate responses across a range from 1 mrem/hr to 100,000 mrem/hr, with clear correlation between dose rate and group count.
Read this paper