This paper presents the state-of-the-art detector technologies developed for the Compact Linear Collider (CLIC), a proposed high-energy, high-luminosity electron-positron collider. It details innovative silicon vertex and tracking detectors, highly granular calorimeters, and advanced readout electronics—featuring hybrid ASICs like CLICpix2 and Timepix3—enabling precise particle tracking, energy measurement, and time resolution under extreme beam conditions, with key results from test-beam campaigns and Monte Carlo simulations validating performance for precision physics at 3 TeV.
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
Motivation & Objective
- To address the stringent detector requirements imposed by CLIC's high-luminosity, short-bunch, and low-emittance beam parameters.
- To develop low-mass, high-granularity vertex and tracking detectors with sub-100 μm spatial resolution and picosecond time resolution.
- To design highly granular calorimeters with sub-centimeter segmentation for precise energy and shower reconstruction via particle flow algorithms.
- To enable power-pulsed operation and low occupancy in detector subsystems through advanced front-end electronics and radiation-hard sensor technologies.
- To validate detector concepts through extensive R&D, test-beam campaigns, and simulation frameworks like Allpix2 and Corryvreckan.
Proposed method
- Implementation of hybrid silicon pixel and strip sensors with fine-pitch bump bonding for high-resolution vertexing and tracking.
- Development of custom front-end ASICs (CLICpix, CLICpix2, Timepix3) with time-over-threshold and time-of-flight capabilities for precise energy and timing measurements.
- Use of highly granular scintillator-tungsten and scintillator-steel calorimeters (CALICE prototypes) for detailed shower profiling and particle flow reconstruction.
- Employment of the Allpix2 Monte Carlo simulation framework to model full detector response, including charge collection and noise.
- Utilization of beam telescopes (e.g., Timepix-based systems) for in-situ characterization of sensor and ASIC performance under beam conditions.
- Application of software compensation techniques to improve energy resolution in hadronic calorimeters using detailed shower topology information.
Experimental results
Research questions
- RQ1How can silicon pixel and strip sensors with sub-100 μm pitch and picosecond time resolution be realized for CLIC's demanding vertexing and tracking requirements?
- RQ2What are the optimal sensor and readout electronics architectures to achieve low power consumption and high dynamic range under high-rate, pulsed beam conditions?
- RQ3To what extent can highly granular calorimeters with sub-centimeter segmentation enable precise particle flow reconstruction and energy resolution below 1% for jets and hadrons?
- RQ4How do radiation hardness and long-term stability of sensors and ASICs perform under CLIC's expected radiation levels and beam-induced backgrounds?
- RQ5Can advanced simulation and reconstruction frameworks (e.g., Allpix2, Corryvreckan) accurately predict detector performance and support R&D for CLIC?
Key findings
- CLICpix2 ASIC achieves 25 ps time resolution and 100 μm spatial resolution, enabling precise timing and tracking in high-rate environments.
- Test-beam results from the CALICE scintillator-tungsten hadronic calorimeter demonstrate a hadronic energy resolution of 30 GeV for 100 GeV pions, validating particle flow reconstruction.
- Software compensation techniques applied to CALICE data reduce energy resolution uncertainty by up to 30% compared to hardware-only methods.
- Monte Carlo simulations using Allpix2 show excellent agreement with test-beam data for charge collection and signal formation in silicon sensors.
- Radiation hardness studies confirm that silicon sensors and ASICs (e.g., Timepix3) maintain performance after irradiation to fluences exceeding 10^15 n_eq/cm².
- The luminosity detector (LumiCal) prototype achieves a Molière radius measurement of 15.5 mm, critical for forward physics and luminosity monitoring.