[Paper Review] Commissioning of the highly granular SiW-ECAL technological prototype
This paper presents the commissioning and beam test performance of a highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) technological prototype designed for the International Linear Collider (ILC). The prototype achieves stable signal recording down to 0.5 MIP with no performance degradation in high magnetic fields, demonstrating successful integration of compact, power-pulsed front-end electronics and advanced trigger filtering for future particle physics applications.
In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number similar to that envisaged for e.g. the ILD Detector of the International Linear Collider (ILC). The analysis demonstrates the capability of the detector to record signals as low as 0.5 MIP. Further, no loss of performance has been observed when operating the detector in a high magnetic field.
Motivation & Objective
- To develop and test a compact, low-power, highly granular SiW-ECAL prototype suitable for the International Linear Collider (ILC) detector.
- To validate the performance of power-pulsed front-end electronics embedded within the detector structure under beam conditions.
- To address and mitigate spurious trigger events (e.g., empty triggers, retriggers, plane events) in high-rate beam environments.
- To demonstrate signal resolution down to 0.5 MIP and robust operation in high magnetic fields, critical for ILC physics goals.
Proposed method
- Utilized a 30-layer SiW-ECAL prototype with 320 µm thick silicon sensors segmented into 256 channels (5×5 mm²) and tungsten absorbers.
- Integrated power-pulsed front-end electronics (FEV11_COB) with chip-on-board (COB) packaging to reduce thickness to 1.2 mm and improve compactness.
- Employed SKIROC2a ASICs with optimized OR64 signal timing to reduce empty trigger rates from ~17% to 2–3%.
- Implemented real-time monitoring and filtering of fake triggers (retriggers, plane events) via data acquisition tagging and post-processing.
- Conducted beam tests at DESY using 3 GeV positrons at 2–3 kHz repetition rate to evaluate low-energy response and noise performance.
- Analyzed signal-to-noise ratios and hit detection efficiency, with special focus on edge-channel crosstalk and power supply-induced artifacts.
Experimental results
Research questions
- RQ1Can the SiW-ECAL technological prototype achieve stable signal recording at the 0.5 MIP threshold under beam conditions?
- RQ2How does the performance of the prototype degrade or remain robust when operated in a high magnetic field?
- RQ3What is the effectiveness of the power-pulsing scheme and COB-embedded front-end electronics in reducing power consumption and maintaining signal integrity?
- RQ4To what extent do spurious trigger events (e.g., retriggers, plane events) affect data quality, and can they be effectively filtered?
- RQ5How do power supply instabilities and routing issues correlate with the appearance of fake trigger events in distant ASICs?
Key findings
- The prototype successfully recorded signals as low as 0.5 MIP, demonstrating high sensitivity for minimum-ionizing particles.
- No degradation in performance was observed when operating the detector in a high magnetic field, confirming compatibility with ILC conditions.
- The empty trigger rate was reduced from ~17% to 2–3% through optimization of the OR64 signal timing in the SKIROC2a ASIC.
- Retrigger and plane event rates were found to be higher in ASICs distant from the beam spot and near channels with suspected routing issues, reaching up to 40% in some cases.
- A correlation of ~1.6 µs was observed between ASIC memory full signals and the onset of retriggers in other areas, indicating power supply baseline distortion.
- The use of guard-ring-free silicon wafers with stealth dicing reduced edge crosstalk and parasitic signal rates to negligible levels.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.