Skip to main content
QUICK REVIEW

[Paper Review] Describing the response of saturated SiPMs

K. Kotera, Weonseok Choi|arXiv (Cornell University)|Oct 5, 2015
Semiconductor materials and interfacesPhysics and Astronomy4 references11 citations
TL;DR

This paper proposes a modified analytical function, NLO′_C·A, that accurately models SiPM response across both low and highly saturated light levels by incorporating pixel recovery dynamics during single light pulses. The model achieves a linear increase in signal at high intensities—matching real SiPM behavior—using only seven fitting parameters, significantly improving upon the standard LO′ model while maintaining practical simplicity for detector calibration.

ABSTRACT

We have developed a function which describes SiPM response in both small signal and highly saturated regimes. The function includes the reactivation of SiPM pixels during a single input light pulse, and results in an approximately linear increase of SiPM response in the highly saturated regime, as observed in real SiPMs. This article shows that the function can accurately describe the measured response of real SiPM devices over a wide range of signal intensities.

Motivation & Objective

  • To address the non-linear response of SiPMs at high light intensities, particularly the observed linear increase in signal under saturation.
  • To develop a simplified yet accurate function that captures pixel recovery during single light pulses, which the standard LO′ model fails to describe.
  • To provide a practical, parameter-efficient function suitable for real-world SiPM calibration in experimental physics.
  • To quantify the influence of recovery dynamics, crosstalk, and afterpulsing on SiPM response across diverse device and scintillator configurations.

Proposed method

  • The authors introduce a modified function, NLO′_C·A, which extends the LO′ model by including a recovery term based on pixel recovery ratio α and a time-dependent factor β to model multiple firings per pixel during a pulse.
  • The model incorporates parameters for crosstalk (P_cross) and afterpulsing (P_after), which are fitted to experimental data to account for secondary and delayed photon detection events.
  • Experimental data were collected from 73 SiPM devices (1600-pixel MPPCs) using scintillator strips coupled with wavelength-shifting fibers and direct MPPC-scintillator coupling, with laser pulses of 31 ps FWHM.
  • Charge integration over 150 ns using a charge-sensitive ADC allowed conversion of output signals to effective fired pixel counts, calibrated against a PMT with known linear response.
  • Fitting was performed using a seven-parameter function that includes N_pix, ε (effective detection efficiency), α (recovery ratio), β (moderating factor), and P_cross and P_after for crosstalk and afterpulsing.
  • Temperature-dependent gain corrections were applied using a previously measured linear relationship between gain and temperature, ensuring consistent calibration across measurements.

Experimental results

Research questions

  • RQ1How can the SiPM response in the highly saturated regime be accurately modeled when standard LO′ models fail to reproduce the observed linear increase in signal?
  • RQ2What role does pixel recovery during a single light pulse play in shaping the SiPM response function at high photon fluxes?
  • RQ3How do parameters like recovery ratio α and moderating factor β influence the high-intensity response behavior of SiPMs?
  • RQ4To what extent do crosstalk and afterpulsing parameters distort the fitting function, and how do they vary across different SiPM and scintillator configurations?
  • RQ5Can a simplified function with only seven parameters achieve both accuracy and practicality for detector calibration in real experiments?

Key findings

  • The NLO′_C·A model successfully describes SiPM response over a wide dynamic range, including the experimentally observed linear increase in signal at high saturation levels.
  • The recovery ratio α was measured at 0.295 ± 0.04 (RMS) across 72 samples, with a reduced value of 0.24 ± 0.02 in direct MPPC-scintillator coupling, indicating stronger suppression of recovery with shorter pulse durations.
  • The moderating factor β was found to be 11.7 ± 2.7 (RMS), with a lower value of 6.9 ± 0.6 in direct coupling, suggesting a stronger influence of pulse shape on recovery dynamics.
  • The crosstalk parameter P_cross had a mean of 0.22 across 72 samples, higher than the directly measured value of 0.11 ± 0.02, indicating potential systematic distortions in fitting.
  • The afterpulsing parameter P_after showed high fluctuations (RMS 0.17, mean 0.08), with 29% of samples yielding negative values—impossible for real afterpulsing—highlighting systematic uncertainties in fitting.
  • Despite parameter fluctuations, the model achieves a reduced χ² close to unity when systematic uncertainties are included, indicating strong agreement with experimental data.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.