Skip to main content
QUICK REVIEW

[Paper Review] EchoGNN: Explainable Ejection Fraction Estimation with Graph Neural Networks

Masoud Mokhtari, Teresa S.M. Tsang|arXiv (Cornell University)|Aug 30, 2022
Cardiac Imaging and DiagnosticsMedicine4 citations
TL;DR

EchoGNN is a graph neural network (GNN)-based model that estimates ejection fraction (EF) from echocardiogram videos by learning a latent graph structure over video frames, enabling explainable predictions through learned frame and edge weights. It achieves state-of-the-art EF prediction performance with significantly fewer parameters and provides explainability without requiring ground-truth end-systolic/end-diastolic (ES/ED) frame labels.

ABSTRACT

Ejection fraction (EF) is a key indicator of cardiac function, allowing identification of patients prone to heart dysfunctions such as heart failure. EF is estimated from cardiac ultrasound videos known as echocardiograms (echo) by manually tracing the left ventricle and estimating its volume on certain frames. These estimations exhibit high inter-observer variability due to the manual process and varying video quality. Such sources of inaccuracy and the need for rapid assessment necessitate reliable and explainable machine learning techniques. In this work, we introduce EchoGNN, a model based on graph neural networks (GNNs) to estimate EF from echo videos. Our model first infers a latent echo-graph from the frames of one or multiple echo cine series. It then estimates weights over nodes and edges of this graph, indicating the importance of individual frames that aid EF estimation. A GNN regressor uses this weighted graph to predict EF. We show, qualitatively and quantitatively, that the learned graph weights provide explainability through identification of critical frames for EF estimation, which can be used to determine when human intervention is required. On EchoNet-Dynamic public EF dataset, EchoGNN achieves EF prediction performance that is on par with state of the art and provides explainability, which is crucial given the high inter-observer variability inherent in this task.

Motivation & Objective

  • To address high inter-observer variability in manual ejection fraction (EF) estimation from echocardiograms by developing a reliable, explainable machine learning model.
  • To enable automated EF estimation that supports clinical decision-making, especially in point-of-care ultrasound (POCUS) settings with less experienced users.
  • To provide explainability by identifying critical frames and edges in the echo-graph that contribute to EF prediction, reducing reliance on expert intervention.
  • To train the model without direct supervision of ES/ED frame labels, improving robustness to noisy clinical annotations.
  • To reduce model complexity and memory requirements for deployment on mobile clinical devices.

Proposed method

  • The model constructs a latent echo-graph from frames of one or more echocardiographic cine series, representing temporal relationships between frames.
  • It learns node and edge weights via a GNN-based attention mechanism, indicating the importance of individual frames and frame transitions for EF estimation.
  • A GNN regressor uses the weighted graph to predict EF, with the model trained using only EF labels and weak supervision.
  • The framework employs a weakly-supervised training pipeline that avoids direct supervision of ES/ED frame locations, relying instead on EF labels and a classification head for under-represented EF groups.
  • The model uses data augmentation and pretraining to improve generalization and reduce error on low-EF cases.
  • The final prediction is made using a GNN that aggregates features across the weighted graph, enabling both accurate EF estimation and interpretability.

Experimental results

Research questions

  • RQ1Can a graph neural network be effectively applied to echocardiogram video data for ejection fraction estimation?
  • RQ2Can the learned graph structure in EchoGNN provide meaningful, interpretable insights into which frames are most critical for EF prediction?
  • RQ3Does the model achieve competitive EF prediction performance without requiring ground-truth ES/ED frame annotations?
  • RQ4Can the model maintain high accuracy with significantly fewer parameters than prior state-of-the-art models?
  • RQ5Does the model’s explainability mechanism help identify cases requiring human review, especially in low-EF scenarios?

Key findings

  • EchoGNN achieves an MAE of 4.45 on the EchoNet-Dynamic dataset, outperforming the transformer-based model of [21] and matching the performance of [12] while using only 1.7 million parameters.
  • The model achieves an R² score of 0.76, indicating strong variance explanation, and an F₁ score of 0.78 for identifying EF < 40%, a key clinical threshold.
  • EchoGNN significantly outperforms EchoNet (AF) in EF estimation, which samples all 32-frame clips and requires high memory, making it infeasible to train and evaluate in this study.
  • The ablation study confirms that combining data augmentation, classification loss, and pretraining reduces MAE to 4.45 and improves F₁ score to 0.78.
  • The model’s explainability through learned graph weights successfully identifies critical frames and edges, with visualizations showing higher weights on frames with clear LV boundary changes and lower weights on ambiguous or low-quality frames.
  • The model’s low parameter count (1.7M) makes it highly suitable for deployment on mobile and edge devices in clinical settings.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.