[Paper Review] Generative Mask Pyramid Network for CT/CBCT Metal Artifact Reduction with Joint Projection-Sinogram Correction
This paper proposes a generative mask pyramid network (MPN) with joint projection-sinogram correction for metal artifact reduction (MAR) in CT/CBCT, leveraging adversarial learning and context-aware inpainting to recover anatomically consistent structures. The method outperforms state-of-the-art approaches by reducing secondary artifacts and achieving lower RMSE and higher SSIM, especially on large metallic implants without requiring synthesized training data.
A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion methods cannot always produce anatomically consistent information to fill the metal trace, and thus, when the metallic implant is large, significant secondary artifacts are often introduced. In this work, we propose to replace metal artifact affected regions with anatomically consistent content through joint projection-sinogram correction as well as adversarial learning. To handle the metallic implants of diverse shapes and large sizes, we also propose a novel mask pyramid network that enforces the mask information across the network's encoding layers and a mask fusion loss that reduces early saturation of adversarial training. Our experimental results show that the proposed projection-sinogram correction designs are effective and our method recovers information from the metal traces better than the state-of-the-art methods.
Motivation & Objective
- To address the challenge of metal artifacts in CT/CBCT imaging, particularly secondary artifacts from imperfect sinogram or projection completion.
- To eliminate reliance on synthesized metal artifacts during training by treating MAR as an image inpainting problem.
- To improve structural and anatomical consistency in metal-affected regions using joint projection-sinogram correction and adversarial learning.
- To enhance robustness to diverse metal implant shapes and sizes through a novel mask pyramid network and mask fusion loss.
- To achieve better generalization and performance on both synthetic and real clinical datasets without tissue segmentation.
Proposed method
- The method uses a two-stage framework: first, a projection completion module with a mask pyramid network (MPN) generates anatomically plausible surrogates within metal-affected regions using adversarial learning.
- The MPN distills multi-scale mask geometry information across encoding layers to preserve implant shape and structural context.
- A mask fusion loss is introduced to prevent early saturation in adversarial training, improving stability and convergence.
- A sinogram correction module refines the projection-corrected sinograms using a residual prediction network, enforcing inter-projection consistency.
- The generator and discriminator are trained adversarially using LSGAN loss, with the discriminator performing patch-wise real/fake classification.
- The model is trained end-to-end on real metal-free projections with random metal masks applied, avoiding synthetic artifact generation.
Experimental results
Research questions
- RQ1Can joint projection-sinogram correction improve anatomical consistency and reduce secondary artifacts in metal artifact reduction compared to single-domain correction?
- RQ2How does the proposed mask pyramid network enhance feature learning and generalization across diverse metal implant shapes and sizes?
- RQ3To what extent does adversarial training with a mask fusion loss improve the quality and stability of sinogram completion?
- RQ4Does a training strategy based on real metal-free projections with random masks generalize better than methods relying on synthetic metal artifacts?
- RQ5How does the proposed method perform on real clinical data compared to state-of-the-art MAR techniques?
Key findings
- The proposed method achieves the lowest RMSE (29 HU) and highest SSIM (0.94) on synthetic data, significantly outperforming the second-best method (CNNMAR) with RMSE 41 HU and SSIM 0.92.
- For large implants (>1000 pixels), the proposed method shows minimal performance degradation, while segmentation-based methods like NMAR and CNNMAR deteriorate sharply due to inaccurate segmentation.
- On clinical datasets, the method produces qualitatively superior results with fewer secondary artifacts, outperforming BHC, NMAR, LI, and CNNMAR in both visual and quantitative evaluation.
- The joint correction framework reduces RMSE by 29% compared to the second-best method on large implants, demonstrating robustness to complex metal geometries.
- The mask fusion loss effectively prevents early saturation in adversarial training, leading to more stable and higher-quality generation of missing data.
- The method generalizes better to real clinical data than image-domain approaches relying on synthetic artifacts, as evidenced by the performance gap between synthetic and clinical results in CNNMAR.