Skip to main content
QUICK REVIEW

[Paper Review] High-Performance Ultrasonic Levitation with FPGA-based Phased Arrays

William Beasley, Brenda Gatusch|arXiv (Cornell University)|Jan 18, 2019
Microfluidic and Bio-sensing TechnologiesEngineering5 references3 citations
TL;DR

This paper presents a low-cost, high-performance ultrasonic levitation system using an FPGA-based Xilinx Zynq SoC with phased arrays for real-time particle control. It achieves stable, closed-loop levitation with echo-based object detection and position correction, demonstrating speeds up to 460 mm/s with hardware-accelerated phase control.

ABSTRACT

We present a flexible and self-contained platform for acoustic levitation research based on the Xilinx Zynq SoC using an array of ultrasonic emitters. The platform employs an inexpensive ZedBoard and provides fast movement of the levitated objects as well as object detection based on the produced echo. Several features available in the Zynq device are of benefit for this platform: hardware acceleration for the phase calculations, large number of parallel I/Os connected through the FPGA Mezzanine connector (FMC), integrated ADC capabilities to capture echo signals and ease of programmability due to a C-based design flow for both CPU and FPGA. A planar and spherical cap phased arrays are created and we investigate the capabilities and limitations of the different designs to improve the stability of the levitation process.

Motivation & Objective

  • Develop a low-cost, high-performance platform for ultrasonic acoustic levitation suitable for academic and research use.
  • Enable real-time, closed-loop control of levitated particles using echo-based feedback from ultrasonic transducers.
  • Leverage the Zynq SoC’s hardware acceleration and integrated ADC for precise phase control and signal acquisition.
  • Investigate and compare planar and spherical cap phased array configurations for improved levitation stability.
  • Provide open-source hardware and software to foster further research and replication in the field.

Proposed method

  • Implement a phased array system using 64 ultrasonic transducers (32 on top, 32 on bottom) in a spherical cap configuration for beamforming and levitation.
  • Use the Zynq SoC’s programmable logic for hardware-accelerated phase calculations, enabling high refresh rates and fine control over beam steering.
  • Integrate two 40 kHz transducers as receivers to detect echo signals from levitated particles, enabling position feedback.
  • Employ separate frequencies for levitation (25 kHz) and detection (40 kHz) to avoid interference and improve echo signal strength.
  • Utilize the ZedBoard’s 12-bit ADC (2 channels, up to 1 MSPS) for capturing echo signals and enable real-time processing via the ARM processor and FPGA.
  • Design a closed-loop control system that adjusts beam focus based on echo amplitude and phase to maintain particle stability.

Experimental results

Research questions

  • RQ1Can an FPGA-based Zynq SoC platform achieve high-performance ultrasonic levitation with real-time feedback and object detection at low cost?
  • RQ2How does hardware-accelerated phase control compare to software-based control in terms of speed, stability, and refresh rate?
  • RQ3What are the performance differences between planar and spherical cap phased array configurations in terms of levitation stability and beam focusing?
  • RQ4Can echo signals from levitated particles be reliably detected and used for closed-loop position correction using a limited number of ADC channels?
  • RQ5What frequency separation is optimal between levitation and detection transducers to maximize echo signal strength and minimize interference?

Key findings

  • The hardware-accelerated implementation achieved a maximum stable speed of 392 mm/s in linear motion and 460 mm/s in circular motion, outperforming software-only methods due to finer step size control.
  • The system demonstrated stable levitation of EPS spheres at speeds up to 460 mm/s in circular orbits, with a 14.8% increase over the maximum stable speed in linear mode.
  • Echo detection was successfully achieved using 40 kHz transducers for sensing while 25 kHz transducers were used for levitation, resulting in stronger echo signals and improved detection range.
  • The spherical cap array configuration enabled stable levitation of particles in 3D space, as shown in video demonstrations and photographic evidence.
  • The use of separate frequencies (25 kHz for levitation, 40 kHz for detection) significantly improved echo signal-to-noise ratio compared to using the same frequency.
  • The open-source release of PCB schematics, firmware, and software via GitHub enables full replication and extension of the system for multi-particle levitation and advanced feedback control.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.