[Paper Review] Model-Based Calibration of Filter Imperfections in the Random Demodulator for Compressive Sensing
This paper proposes a model-based calibration method for the random demodulator in compressive sensing that corrects filter imperfections by estimating impulse response errors via sampling a known calibrating signal. Using least-squares estimation, the method improves signal reconstruction quality with orders-of-magnitude fewer samples than state-of-the-art DFTTI, achieving up to 50 dB SNR improvement in noiseless reconstruction while requiring only M samples instead of M×N.
The random demodulator is a recent compressive sensing architecture providing efficient sub-Nyquist sampling of sparse band-limited signals. The compressive sensing paradigm requires an accurate model of the analog front-end to enable correct signal reconstruction in the digital domain. In practice, hardware devices such as filters deviate from their desired design behavior due to component variations. Existing reconstruction algorithms are sensitive to such deviations, which fall into the more general category of measurement matrix perturbations. This paper proposes a model-based technique that aims to calibrate filter model mismatches to facilitate improved signal reconstruction quality. The mismatch is considered to be an additive error in the discretized impulse response. We identify the error by sampling a known calibrating signal, enabling least-squares estimation of the impulse response error. The error estimate and the known system model are used to calibrate the measurement matrix. Numerical analysis demonstrates the effectiveness of the calibration method even for highly deviating low-pass filter responses. The proposed method performance is also compared to a state of the art method based on discrete Fourier transform trigonometric interpolation.
Motivation & Objective
- To address signal reconstruction degradation caused by hardware-induced measurement matrix mismatches in compressive sensing systems.
- To develop a low-sample-count calibration method that corrects filter imperfections without modifying hardware or operational frequency.
- To provide a practical, model-based alternative to computationally expensive DFTTI calibration with comparable or better reconstruction quality.
- To enable frequent re-calibration in real-world systems by minimizing calibration sample requirements.
Proposed method
- The method models filter imperfections as an additive error in the discretized impulse response of the low-pass filter in the random demodulator.
- It uses a known calibrating signal to sample the system and estimate the impulse response error via least-squares estimation.
- The estimated error is then used to calibrate the initial measurement matrix, improving its accuracy for subsequent signal reconstruction.
- The calibration framework operates on truncated impulse responses and leverages linear estimation to minimize discrepancy between modeled and actual front-end behavior.
- The method is formulated using a system of equations (27) that estimates the error vector, with performance dependent on the number of calibration samples M_q relative to impulse response length L.
- The approach is compared to DFTTI, which requires M×N samples, while this method uses only M samples, significantly reducing time and resource overhead.
Experimental results
Research questions
- RQ1Can a model-based calibration method effectively correct for filter imperfections in the random demodulator’s analog front-end with minimal calibration samples?
- RQ2How does the proposed method’s performance compare to DFTTI in terms of reconstruction quality and computational cost?
- RQ3What is the impact of the number of calibration samples (M_q) and tones (K) on the accuracy of the impulse response error estimation?
- RQ4Does the method remain robust across different filter types, such as Butterworth and Chebyshev, under significant component deviations?
- RQ5Can the method be used as a practical, low-overhead calibration step in systems requiring frequent recalibration?
Key findings
- The proposed model-based calibration reduced RMSE to 2.5677×10⁻⁷ for Chebyshev filters and 3.3824×10⁻⁷ for Butterworth filters, significantly improving reconstruction quality.
- The method achieved a reconstruction SNR of up to 180.98 dB for Chebyshev filters and 173.75 dB for Butterworth filters, representing a 50 dB improvement over uncalibrated systems.
- Calibration time was reduced to 0.1312 seconds for DFTTI and 0.1457 seconds for MBC, with the proposed method requiring only M samples instead of M×N, reducing sample count by ~12.6k for an 800×12600 problem.
- The method outperformed DFTTI in SNR stability when filter imperfections were large, particularly when M_q ≥ L, and showed significant error reduction even at M_q ≈ 1.2L.
- Performance degradation was observed in the DFTTI-based method when increasing the number of tones K, while the proposed method maintained consistent error correction.
- The method is most effective when M_q ≥ L, and fails to improve or even worsens performance when M_q ≤ L, indicating a critical sample size threshold.