Skip to main content
QUICK REVIEW

[Paper Review] Real-time Prediction of Segmentation Quality

R. H. Robinson, Ozan Oktay|arXiv (Cornell University)|Jun 16, 2018
Advanced X-ray and CT ImagingEngineering7 references13 citations
TL;DR

This paper proposes a deep learning-based method for real-time prediction of cardiovascular MR image segmentation quality using Dice Similarity Coefficient (DSC) as a metric. It achieves a mean absolute error (MAE) of 0.03 with ground truth and 0.14 without, enabling millisecond-scale feedback during scanning to detect poor-quality segmentations before clinical decisions are made.

ABSTRACT

Recent advances in deep learning based image segmentation methods have enabled real-time performance with human-level accuracy. However, occasionally even the best method fails due to low image quality, artifacts or unexpected behaviour of black box algorithms. Being able to predict segmentation quality in the absence of ground truth is of paramount importance in clinical practice, but also in large-scale studies to avoid the inclusion of invalid data in subsequent analysis. In this work, we propose two approaches of real-time automated quality control for cardiovascular MR segmentations using deep learning. First, we train a neural network on 12,880 samples to predict Dice Similarity Coefficients (DSC) on a per-case basis. We report a mean average error (MAE) of 0.03 on 1,610 test samples and 97% binary classification accuracy for separating low and high quality segmentations. Secondly, in the scenario where no manually annotated data is available, we train a network to predict DSC scores from estimated quality obtained via a reverse testing strategy. We report an MAE=0.14 and 91% binary classification accuracy for this case. Predictions are obtained in real-time which, when combined with real-time segmentation methods, enables instant feedback on whether an acquired scan is analysable while the patient is still in the scanner. This further enables new applications of optimising image acquisition towards best possible analysis results.

Motivation & Objective

  • To enable real-time quality assessment of automated cardiac MR segmentation in clinical settings.
  • To detect low-quality segmentations without relying on ground truth labels, crucial for large-scale studies.
  • To reduce the time required for quality evaluation from minutes to milliseconds compared to reverse testing methods.
  • To develop a scalable, deployable framework compatible with real-time segmentation pipelines.
  • To validate performance under both fully-annotated and data-scarce scenarios using transferable quality metrics.

Proposed method

  • A convolutional neural network (CNN) is trained on 12,880 labeled cases to predict DSC scores directly from input MR images.
  • For the zero-shot scenario, the network is trained using quality scores derived from Reverse Testing (RCA) instead of ground truth, enabling use without manual annotations.
  • The RCA-based approach uses 100 reference images with verified segmentations to estimate DSC-like metrics for training.
  • The model predicts DSC on a per-case basis and performs binary classification to distinguish high (>0.5 DSC) and low-quality segmentations.
  • Inference is performed in under 600 ms on CPU and 40 ms on GPU, enabling real-time integration with acquisition workflows.
  • The framework is evaluated on 1,610 test cases from the UK Biobank Imaging Study, with class-wise and whole-heart segmentation analysis.

Experimental results

Research questions

  • RQ1Can a deep learning model predict segmentation quality in real time with high accuracy, even when ground truth is unavailable?
  • RQ2How does the performance of a DSC prediction network compare between scenarios with and without manual annotations?
  • RQ3To what extent can Reverse Testing (RCA) scores serve as a surrogate label for training quality prediction networks?
  • RQ4Can the proposed method achieve sub-second inference time while maintaining clinically relevant accuracy?
  • RQ5How robust is the model to variations in image quality and segmentation boundary errors?

Key findings

  • The model achieved a mean absolute error (MAE) of 0.03 on 1,610 test cases when trained with ground truth, indicating high regression accuracy.
  • Binary classification accuracy reached 97% for distinguishing low-quality (DSC < 0.5) and high-quality (DSC ≥ 0.5) segmentations in the ground truth scenario.
  • In the absence of ground truth, the model achieved an MAE of 0.14 using RCA-derived labels, with 91% binary classification accuracy.
  • Inference time was reduced to 40 ms on GPU and 600 ms on CPU, over 10,000 times faster than traditional RCA (660 seconds).
  • The model demonstrated strong performance across all cardiac structures (LV, LVM, RVC, BG, WH), with lowest error on background and left-ventricular cavity.
  • The framework enables real-time feedback during MRI acquisition, allowing immediate scan reacquisition if segmentation quality is predicted to be poor.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.