TL;DR

This paper introduces the Feasible Planning Region (FPR), a novel method to represent distribution grid expansion costs and operational constraints in systemic power system planning. By integrating physical limits and investment costs across multiple voltage levels and urbanization types, the FPR enables more accurate, cost-reflective optimization of future energy systems, leading to higher distributed solar PV integration and reduced transmission losses compared to simplified models.

ABSTRACT

The shift towards clean energy brings about notable transformations to the energy system. In order to optimally plan a future energy system, it is necessary to consider the influence of several sectors as well as the interaction of the transmission grid and distribution grid. The concept of Feasible Operation Region (FOR) is a detailed approach to representing the operational dependencies between the transmission and distribution grid. However, in previous planning procedures, only a simplified expansion of the distribution grids can be taken into account. With the method presented in this paper, a Feasible Planning Region (FPR) is developed, which represents the operational boundaries of the distribution grids for several expansion stages and thus represents an admissible solution space for the planning of distribution grids in systemic planning approaches. It hence enables a more detailed representation of the necessary distribution grid expansion for the integration of distributed technologies in an optimized energy system of the future. In this paper, we present the method by which the FPR is formed and its integration into an energy system planning formulation. In the results, the FPR is presented for different voltage levels, and its use in power system planning is demonstrated.

Motivation & Objective

  • To address the lack of detailed representation of distribution grid expansion costs and operational constraints in systemic energy system planning.
  • To develop a method that captures the interplay between distribution grid infrastructure investments and physical operational limits across different voltage levels and urbanization types.
  • To enable TSO-DSO coordinated planning by embedding distribution grid feasibility into system-wide optimization models.
  • To demonstrate how including distribution grid costs and constraints alters technology selection and system configuration in future energy systems.

Proposed method

  • The Feasible Planning Region (FPR) is constructed by modeling the operational boundaries of distribution grids across multiple expansion stages, using power flow equations and grid parameters.
  • The FPR integrates physical constraints (e.g., thermal limits, voltage limits) and investment costs for different voltage levels (10–20 kV, 110 kV) and urbanization levels (rural, semi-urban, urban).
  • The method extends the Feasible Operation Region (FOR) concept to include investment cost components, forming a solution space that reflects both feasibility and economic cost of grid expansion.
  • The FPR is embedded into a large-scale energy system optimization model, allowing for coordinated planning of transmission and distribution grids.
  • The approach uses a reduced European network with 37 nodes (one per country) and a greenfield scenario for 2030, based on historical weather data and conventional plant retention.
  • Two scenarios are compared: one without FPR (unlimited capacity, no costs) and one with FPR (costs and physical limits included) to assess impact on system configuration.

Experimental results

Research questions

  • RQ1How does the inclusion of distribution grid expansion costs and physical constraints affect the optimal configuration of a future energy system?
  • RQ2How do different voltage levels and urbanization types influence the shape and cost of the Feasible Planning Region (FPR)?
  • RQ3To what extent does the FPR alter technology deployment, particularly distributed solar PV and wind, compared to simplified models?
  • RQ4What is the impact of FPR on interconnection power flows and transmission losses between transmission and distribution systems?

Key findings

  • The inclusion of FPR leads to a higher deployment of rooftop photovoltaic systems, as they reduce interconnection power flows and avoid costly distribution grid expansion.
  • Scenario B, which includes FPR, shows a 15–20% reduction in transmission losses at the TSO/DSO interface compared to Scenario A, due to localized generation.
  • The FPR model results in a shift from onshore wind to distributed solar PV in urban and semi-urban areas, reflecting the cost and physical feasibility of local generation.
  • The shape and cost of the FPR vary significantly with voltage level and urbanization, with urban areas showing tighter constraints and higher investment costs.
  • The FPR enables a more accurate representation of TSO-DSO coordination, revealing that neglecting distribution grid costs leads to suboptimal system configurations.
  • The study demonstrates that FPR integration alters the optimal energy system mix, favoring decentralized technologies when physical and economic constraints are properly modeled.